3.1.2.2 DeviceNet displays

The status of the DeviceNet module is indicated by the LEDs MS and NS.

LED

(dual)

MS

Module Status

Significance

... ... Slow flashing = 2Hz (0.5s cycle)

OFF

No voltage supply

ON (green)

Normal operation, cyclic exchange of data via DeviceNet

Flashing 0.5s
(green)

Module in standby mode, no connection to one or more FIs. (No
parameters have yet been exchanged. Therefore setpoint specification
via the DeviceNet AC profile is not possible)

The baud rate setting for the DeviceNet bus is invalid.

ON (red):

Error which cannot be acknowledged. The module may need to be
replaced.

Flashing 0.5s
(red)

The module has an error which can be acknowledged

LED

(dual)

NS

Network Status

Significance

... ... Slow flashing = 2Hz (0.5s cycle)

OFF

No voltage supply

The module has not carried out the “Dup_MAC_ID“ test

ON (green)

Normal operation, cyclic exchange of data via DeviceNet

Flashing 0.5s
(green)

The module is online and has carried out the “Dup_MAC_ID” test, but
has not set up communication to the other subscribers

ON (red):

Serious communication error, such as Bus Off, Duplicate MAC ID or
invalid baud rate setting

Flashing 0.5s
(red)

Timeout – The I/O connection or the P151 function has triggered a
timeout error.

The flashing code is displayed for at least 5 seconds.