NORD Drivesystems BU0280 User Manual

Page 14

background image

Supplementary Manual DeviceNet for NORDAC SK 200E

14

Subject to technical amendments

BU 0280 GB

The external technology modules (Technology Unit, SK TU4-...) – designated as the technology unit – are
externally attached to the SK 200E connection unit and are therefore easy to access. Mounting of the SK TU4-
... separate from the frequency inverter is possible by means of the optional wall mounting kit SK TIE4-WMK-
TU

. The electrical connection to the SK 200E is made via the internal system bus. 4 or 5 pin M12 round plug

connectors (for installation in the BUS connection unit SK TI4-TU-BUS) are available as an option for
connection of the field bus cable. The external modules are also available as a version with integrated M12
round plug connectors (SK TU4-xxx-M12). These enable the connection of up to 4 digital inputs and 2 digital
outputs.








NOTE

Modules should not be inserted or removed unless the device is free of voltage. The slots
may only be used for the applicable modules.

Mounting of the external technology unit remote from the frequency inverter is possible
with the additional wall-mounting kit (SK TIE4-WMK-TU). However, a maximum cable
length of 30m should not be exceeded.

The external technology units (SK TU4-...(-M12) cannot be operated without the BUS
connection unit (SK T14-TU-BUS)!


NOTE

Only one technology unit (SK CU4... or SK TU4...) can be connected to a system bus.

Optional external

technology unit, SK TU4-...