Badger Meter M-Series M2000 User Manual
Page 32
Measurements
Totalizer Unit
[USG]
U
The Totalizer Unit parameter establishes the units of measure for the totalizers
To change the Totalizer Unit value, follow these steps from the Measurements menu:
1 Select Totalizer Unit to view the Totalizer Unit display
2 Position the arrow next to one of the following totalizer units:
Code
Totalizer Unit
Code
Totalizer Unit
L
Liters
UKG
Imperial Gallons
HL
HectoLiters
Lb
Pounds
M
3
Cubic Meters
Oz
Fluid Ounces
CFt
Cubic Feet
Aft
Acre Feet
USG
U S Gallons
BBL
Barrel
MG
MegaGallons
—
—
3 Press [E] to save the totalizer unit and return to the Measurements menu
Full Scale Flow
[Factory Set]
U
The Full Scale Flow parameter sets the maximum flow the system is expected to measure This
parameter has influence on other system parameters These parameters include:
• Frequency Output – Full scale frequency is observed at full scale flow
• Low Flow Cutoff – Changes to full scale flow affect the measuring cut-off threshold of the meter
• Alarm Outputs – Changes to full scale flow adjusts the thresholds for generating set point alarms
• Pulse Outputs – Changes to full scale flow adjusts the pulse frequency and duty cycle
• Analog Outputs – Changes to full scale flow adjusts the interpretation of the analog output signal
Change the full scale flow based on the meter size and the application’s requirements Verify that the
full scale flow falls within the meter’s suggested flow range limits In terms of flow velocity, the meter's
limits are from 0 1 to 39 4 feet/second
The full scale flow is valid for both flow directions
NOTE:
N
If the flow rate exceeds the full scale setting, an error message indicates that the configured full
scale range has been exceeded However, the meter will continue to measure This will affect
the latency of the pulse outputs and possibly cause overflow Furthermore, the analog output
may also be placed in alarm mode
To change the Full Scale Flow, follow these steps from the Measurements menu:
1 Select Full Scale Flow to view the Full Scale Flow display
2 Set the full scale flow value to the desired setting
3 Press [E] to save the full scale flow value and return to the Measurements menu