Operation – KROHNE H250 M40 FOUNDATION FIELDBUS User Manual

Page 56

background image

4

OPERATION

56

H250 M40

www.krohne.com

02/2014 - 4001208201 - AD H250 M40 FF R02 en

EU_0

Engineering Unit 0

RW

The engineering unit value which represents the lower end of

range of the associated block parameter.

0.0

Units Index

RW

Setting:

All units are possible.

Decimal Point

RW

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

0

OUT_TRIP

OUT_TRIP

OUT_TRIP

OUT_TRIP

Output Trip

Output Trip

Output Trip

Output Trip

RW

The first discrete output.

Status

RW

Setting:

Good Non Cascade / Good Cascade / Uncertain / Bad Not

Connected / Bad

Bad Not Connected

Value

RW

Setting:

0: Off / 1: On

Off

OUTAGE_LIM

OUTAGE_LIM

OUTAGE_LIM

OUTAGE_LIM

Outage Limit

Outage Limit

Outage Limit

Outage Limit

RW

The maximum tolerated duration for power failure.

0

Setting:

Positive or 0

PCT_INCL

PCT_INCL

PCT_INCL

PCT_INCL

Percentage

Percentage

Percentage

Percentage

Increment

Increment

Increment

Increment

Calculation

Calculation

Calculation

Calculation

R

Indicates the percentage of inputs with good status compared

to the ones with bad or uncertain and bad status.

0.0

PRE_TRIP

PRE_TRIP

PRE_TRIP

PRE_TRIP

Pre Trip

Pre Trip

Pre Trip

Pre Trip

RW

Adjusts the amount of mass, volume or energy that should set

OUT_PTRIP when the integration reaches (TOTAL_SP -

PRE_TRIP) when counting up or PRE_TRIP when counting

down.

0

Setting:

Positive or 0

PULSE_VAL1

PULSE_VAL1

PULSE_VAL1

PULSE_VAL1

Pulse Value 1

Pulse Value 1

Pulse Value 1

Pulse Value 1

RW

Determines the mass, volume or energy per pulse.

0.0

Setting:

Positive or 0

PULSE_VAL2

PULSE_VAL2

PULSE_VAL2

PULSE_VAL2

Pulse Value 2

Pulse Value 2

Pulse Value 2

Pulse Value 2

RW

Determines the mass, volume or energy per pulse.

0.0

Setting:

Positive or 0

RESET_CONFIRM

RESET_CONFIRM

RESET_CONFIRM

RESET_CONFIRM

Reset Confirm

Reset Confirm

Reset Confirm

Reset Confirm

RW

Momentary discrete value which can be written by a host to

enable further resets, if the option confirm reset in

INTEG_OPTS is chosen.

Status

RW

Setting:

Good Non Cascade / Good Cascade / Uncertain / Bad Not

Connected / Bad / Bad No Comm with Last Useable Value

(LUV)

Bad Not Connected

Value

RW

Setting:

0: Off / 1: On

Off

RESET_IN

RESET_IN

RESET_IN

RESET_IN

Reset Input

Reset Input

Reset Input

Reset Input

RW

Reset the totalizers.

Status

RW

Setting:

Good Non Cascade / Good Cascade / Uncertain / Bad Not

Connected / Bad / Bad No Comm with Last Useable Value

(LUV)

Bad Not Connected

Value

RW

Setting:

0: Off / 1: On

Off

REV_FLOW1

REV_FLOW1

REV_FLOW1

REV_FLOW1

Reverse Flow 1

Reverse Flow 1

Reverse Flow 1

Reverse Flow 1

R/W

Indicates reverse flow when true.

Integrator Block

Parameter
DD Name

Access

Description
settings

Initial

AD_H250_M40_FF_R02_en_4001208201_PRT.book Page 56 Friday, February 21, 2014 11:25 AM