4
OPERATION
56
H250 M40
www.krohne.com
02/2014 - 4001208201 - AD H250 M40 FF R02 en
EU_0
Engineering Unit 0
RW
The engineering unit value which represents the lower end of
range of the associated block parameter.
0.0
Units Index
RW
Setting:
All units are possible.
Decimal Point
RW
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the
specified parameter.
0
OUT_TRIP
OUT_TRIP
OUT_TRIP
OUT_TRIP
Output Trip
Output Trip
Output Trip
Output Trip
RW
The first discrete output.
Status
RW
Setting:
Good Non Cascade / Good Cascade / Uncertain / Bad Not
Connected / Bad
Bad Not Connected
Value
RW
Setting:
0: Off / 1: On
Off
OUTAGE_LIM
OUTAGE_LIM
OUTAGE_LIM
OUTAGE_LIM
Outage Limit
Outage Limit
Outage Limit
Outage Limit
RW
The maximum tolerated duration for power failure.
0
Setting:
Positive or 0
PCT_INCL
PCT_INCL
PCT_INCL
PCT_INCL
Percentage
Percentage
Percentage
Percentage
Increment
Increment
Increment
Increment
Calculation
Calculation
Calculation
Calculation
R
Indicates the percentage of inputs with good status compared
to the ones with bad or uncertain and bad status.
0.0
PRE_TRIP
PRE_TRIP
PRE_TRIP
PRE_TRIP
Pre Trip
Pre Trip
Pre Trip
Pre Trip
RW
Adjusts the amount of mass, volume or energy that should set
OUT_PTRIP when the integration reaches (TOTAL_SP -
PRE_TRIP) when counting up or PRE_TRIP when counting
down.
0
Setting:
Positive or 0
PULSE_VAL1
PULSE_VAL1
PULSE_VAL1
PULSE_VAL1
Pulse Value 1
Pulse Value 1
Pulse Value 1
Pulse Value 1
RW
Determines the mass, volume or energy per pulse.
0.0
Setting:
Positive or 0
PULSE_VAL2
PULSE_VAL2
PULSE_VAL2
PULSE_VAL2
Pulse Value 2
Pulse Value 2
Pulse Value 2
Pulse Value 2
RW
Determines the mass, volume or energy per pulse.
0.0
Setting:
Positive or 0
RESET_CONFIRM
RESET_CONFIRM
RESET_CONFIRM
RESET_CONFIRM
Reset Confirm
Reset Confirm
Reset Confirm
Reset Confirm
RW
Momentary discrete value which can be written by a host to
enable further resets, if the option confirm reset in
INTEG_OPTS is chosen.
Status
RW
Setting:
Good Non Cascade / Good Cascade / Uncertain / Bad Not
Connected / Bad / Bad No Comm with Last Useable Value
(LUV)
Bad Not Connected
Value
RW
Setting:
0: Off / 1: On
Off
RESET_IN
RESET_IN
RESET_IN
RESET_IN
Reset Input
Reset Input
Reset Input
Reset Input
RW
Reset the totalizers.
Status
RW
Setting:
Good Non Cascade / Good Cascade / Uncertain / Bad Not
Connected / Bad / Bad No Comm with Last Useable Value
(LUV)
Bad Not Connected
Value
RW
Setting:
0: Off / 1: On
Off
REV_FLOW1
REV_FLOW1
REV_FLOW1
REV_FLOW1
Reverse Flow 1
Reverse Flow 1
Reverse Flow 1
Reverse Flow 1
R/W
Indicates reverse flow when true.
Integrator Block
Parameter
DD Name
Access
Description
settings