Operation – KROHNE H250 M40 FOUNDATION FIELDBUS User Manual
Page 37
OPERATION
4
37
H250 M40
www.krohne.com
02/2014 - 4001208201 - AD H250 M40 FF R02 en
VALUE
Value
R
A numerical quantity entered by a user or calculated by the
algorithm.
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
RANGE_3
RANGE_3
RANGE_3
RANGE_3
mass flow range
The High and Low range limit values, the engineering units code
and the number of digits to the right of the decimal point to be
used to display the Primary Value.
EU_100
max value
R
The engineering unit value which represents the upper end of
range of the associated block parameter.
100
EU_0
min value
R
The engineering unit value which represents the lower end of
range of the associated block parameter.
0.0
UNITS_INDEX
Units Index
RW
Device Description units code index for the engineering unit
descriptor for the associated block value.
kg/h
Setting:
•
g/s, min, h, d
•
kg/s, min, h, d
•
t/s, min, h, d
•
lb/s, min, h, d
•
STon/s, min, h, d
•
LTon/s, min, h, d
•
MLB/H
DECIMAL
Decimal
R
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the specified
parameter.
0
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
TYPE_4
TYPE_4
TYPE_4
TYPE_4
Primary Value
Type
R
The type of measurement represented by the primary value. For
Example: Mass Flow, Absolute Pressure, Differential
Temperature.
level
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
4444
level
The measured level value and status of available to the Function
Block.
STATUS
Status
R
Digital transducers, unlike their analog versions, can detect faults
that make the measurement bad or prevent the actuator from
responding. This additional, valuable information will be passed
along with each transmission of a data value in the form of a
status attribute.
VALUE
Value
R
A numerical quantity entered by a user or calculated by the
algorithm.
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
RANGE_4
RANGE_4
RANGE_4
RANGE_4
level range
The High and Low range limit values, the engineering units code
and the number of digits to the right of the decimal point to be
used to display the Primary Value.
EU_100
max value
R
The engineering unit value which represents the upper end of
range of the associated block parameter.
15.0
EU_0
min value
R
The engineering unit value which represents the lower end of
range of the associated block parameter.
0.0
UNITS_INDEX
Units Index
RW
Device Description units code index for the engineering unit
descriptor for the associated block value.
m
Setting:
•
m
•
cm
•
mm
•
ft
•
in
•
yd
DECIMAL
Decimal
R
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the specified
parameter.
0
SECONDARY_VAL
SECONDARY_VAL
SECONDARY_VAL
SECONDARY_VAL
UE
UE
UE
UE
electronic
temperature
The measured electronic temperature value and status of
available to the Function Block.
Transducer Block
Parameter
DD Name
Access
Description
settings
Initial