Operation – KROHNE H250 M40 FOUNDATION FIELDBUS User Manual

Page 31

background image

OPERATION

4

31

H250 M40

www.krohne.com

02/2014 - 4001208201 - AD H250 M40 FF R02 en

NORMAL

Normal

RW

This is the mode which the block should be set to during normal

operating conditions.

Auto

Setting:

Auto

OOS

ST_Rev

ST_Rev

ST_Rev

ST_Rev

Static Revision

R

The revision level of the static data associated with the function

block. The revision value will be incremented each time a static

parameter value in the block is changed.

0

Setting:

0...65635

STRATEGY

STRATEGY

STRATEGY

STRATEGY

Strategy

RW

The strategy field can be used to identify grouping of blocks. This

data is not checked or processed by the block.

0

Setting:

0...65635

TAG_DESC

TAG_DESC

TAG_DESC

TAG_DESC

Tag Description

RW

The user description of the intended application of the block.

spaces

Setting:

≤32 digits

BLOCK_ALM

BLOCK_ALM

BLOCK_ALM

BLOCK_ALM

Block Alarm

The block alarm is used for all configuration, hardware,

connection failure or system problems in the block. The cause of

the alert is entered in the subcode field. The first alert to become

active will set the "Active" status in the "Status" attribute. As soon

as the "Unreported" status is cleared by the alert reporting task,

another block alert may be reported without clearing the "Active"

status, if the subcode has changed.

UNACKNOWLEDG

ED

Unacknowledged

RW

A discrete enumeration which is set to "Unacknowledged" when

an alarm occurs, and set to "Acknowledged" by a write from a

human interface device or other entity which can acknowledge

that the alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized

Acknowledged

Unacknowledged

ALARM_STATE

Alarm State

R

A discrete enumeration which gives an indication of whether the

alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized

Clear-Reported

Clear-Not Reported

Active-Reported

Active-Not Reported

TIME_STAMP

Time Stamp

R

The time when evaluation of the block was started and a change

in alarm/event state was detected that is unreported. The time

stamp value will be maintained constant until alert confirmation

has been received - even if another change of state occurs.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Transducer Block

Parameter
DD Name

Access

Description
settings

Initial

AD_H250_M40_FF_R02_en_4001208201_PRT.book Page 31 Friday, February 21, 2014 11:25 AM