beautypg.com

Altosonic – KROHNE UFM 600T EN User Manual

Page 81

background image

F.1

General

Measuring beam

1

Diameter range

50 ...

≥ 3000 mm (2” ... ≥120”)

Pipe wall thickness

≤ 40 mm ( ≤ 1.6”)

Pipe wall materials

metal,

plastics,

ceramics,

asbestos-cement with or without
firmly attached linings or coatings

Fluids

any clean homogeneous liquid
with a gaseous or solid particle
content

≤1% by volume

Fluid temp.

-25 to +120 °C (-13 to 248 °F)

Error limits

1 to 3%, depending on application

Reproducibility

up to 0.2%

Time constant

0.04 to 3600 s

Outputs

current, frequency/pulse and RS
232 for data transfer to PC

Display

for indication of all measuring data,
calculated transducer distance,
error messages and transit time

Measured

values

volumetric flow rate, total flow,
transit time and flow direction (for-
ward/reverse)

Cable length:
Standard

5 m (15 ft)

Optional

> 5 m...

≤ 300 m( >15 ft...≤ 900 ft)

78

ALTOSONIC

Technical Data