Page 63

background image

3.3.0 CURR. OUTP.I

:

set up analog current
output

3.3.1 FUNCTION I

:

Program the analog
current output

Select an output option using the key and press
to store:

2 DIR

:

Enables flow measurement in 2 direc-
tions(+ and -) without change

of

polarity in the output signal (Fig. D.3)

TRAN. TIME

:

Output signal is proportional to
the measured transit time of the
acoustic signal.

NOTE: this function requires:
- current setting at zero flow, Fct. 3.3.2
- current setting at full flow, Fct. 3.3.3
- transit time at full flow, Fct. 3.1.2
(see example in description of Fct. 3.1.2)

NO SIGNAL

:

Output signal indicates "signal loss".

OFF

:

No current output.

F/R IND. I

:

Output signal as flow direction
indication, 0% at + flow direction
and 100% at -flow direction
(fig. D.4).

1 DIR

:

Flow measurement in 1 direction
(+) only. (Fig. D.5)

I < I 0 PCT

:

Allows the output signal to drop
below the programmed value for
0% flow at negative (-) flow
direction. If 10 mA is programmed for
0% flow (Fct.3.3.2) and 20 mA for
100% (Fct. 3.3.3) then the output will

60

ALTOSONIC

Programming mode

UFM 600 T