8.4 Flow tables
Measuring ranges
Flow rate limits
Size
Q
min
Q
max
Q
min
Q
max
DN - EN 1092-1 NPS - ASME B16.5
[m
3/
h]
[gph]
Water
15
½
0.45
5.0
119
1321
25
1
0.81
11.40
214
3012
40
1½
2.04
28.57
539
7547
50
2
3.53
49.47
933
13069
80
3
7.74
108.37
2045
28629
100
4
13.30
186.21
3514
49192
150
6
30.13
421.86
7960
111445
200
8
52.66
792.42
13911
209335
250
10
90.5
1266.8
23908
334653
300
12
113.41
1839.8
29960
486024
Values based on water at 20°C / 68°F
Air
15
½
6.79
32.56
1794
8602
25
1
10.20
114.0
2695
30116
40
1½
25.35
326.63
6697
86287
50
2
43.89
565.49
11595
149388
80
3
96.14
1238.60
25398
327207
100
4
165.19
2128.27
43639
562236
150
6
374.23
4821.57
98862
1273738
200
8
702.95
9056.8
185700
2392553
250
10
1123.7
14478
29685
3824683
300
12
1632.1
21028
431155
55550104
Values based on air at 20°C / 68°F and 1.013 bar abs / 14.891 psig
Product
Nominal sizes
Minimum flow rates
Maximum flow rates
EN
ASME
[m/s]
[ft/s]
[m/s]
[ft/s]
Liquids
DN15…300
½…
12"
0.5x(998/ρ)
0.5
1
1.64x(998/ρ)0.5
2
7x(998/ρ)
0.47
1
23x(998/ρ)0.47
2
Gas, steam
DN15…300
½…
12"
6x(1.29/ρ)
0.5
3
16.4x(1.29/ρ)0.5
4
7x(998/ρ)
0.47
3
23x(998/ρ)0.47
4
ρ = operating density [kg/m
3
]
1 Minimum flow rate 0.3 m/s - maximum flow rate 7 m/s
2 Minimum flow rate 0.984 ft/s - maximum flow rate 23 ft/s
3 Minimum flow rate 2 m/s - maximum flow rate 80 m/s; DN15 up to 45 m/s and DN25 up to 70 m/s
4 Minimum flow rate 6.6 ft/s - maximum flow rate 262 ft/s; DN15 up to 148 ft/s and DN25 up to 230 ft/s