Safety instructions

1.1 Intended use

The vortex flowmeters are made to measure the flow of gases, vapours and liquids.

The devices are particularly suitable for the measurement of:

• Clean liquids with low viscosity (< 10 cP)
• Hydrocarbons with low viscosity (< 10 cP)
• Water
• Chemicals with low corrosiveness
• Saturated steam
• Superheated steam, including CIP and SIP applications in the food industry
• Industrial gases

The devices are rated for the following flow velocities:

• Liquids: 0.3...7 m/s / 1.0...23 ft/s
• Gases and steam: 2.0...80 m/s / 6.6...262 ft/s

DN15: 3.0...45 m/s / 9.8...148 ft/s; DN25: 2.0...70 m/s / 6.6...230 ft/s

If the danger of waterhammers can occur in steam networks appropriate condensate separators
have to be installed.
Suitable measures must be taken to avoid water cavitation if it is a possible risk.

• The sensors are made from Stainless Steel 316 L (1.4404) or Hastelloy

®

C22.

• In your project planning, please observe the data given in the corrosion tables.
• The pressure-bearing parts have been designed and rated for stationary operation taking into

account the maximum pressure and temperature.

• Observe the data indicated on the nameplate for PS, TS and PT (PED 97/23/EC).
• External forces and moments, caused e.g. by pipe stresses, have not been taken into account.

Primarily, volumetric flow and temperature are measured, with pressure measurement as an
option. From these parameters the measuring device calculates the mass flow or standard
volumetric flow using pre-programmed density data and then exports the measured values via
various communication interfaces.

CAUTION!
Responsibility for the use of the measurement devices with regard to suitability, intended use
and corrosion resistance of the used materials against the measured fluid lies solely with the
operator.