3

INSTALLATION

26

OPTISWIRL 4070

www.krohne.com

02/2013 - 4000150606 MA OPTISWIRL4070C R07 en

3.4.7 Heat insulation

CAUTION!
The area above the converter support must not be heat-insulated.
The heat insulation 3 may only extend to the maximum height 1 shown below up to the
connecting screws of the measuring sensor.

Figure 3-7: Heat insulation on connection piece and signal cable

1 Max. height of insulation up to intermediate piece between measuring sensor and signal converter
2 Max. thickness of the insulation up to the bend of the pressure pipe
3 Insulation

CAUTION!
The heat insulation 3 may only extend as far as the bend of the pressure sensing line 2.

MA_OPTISWIRL4070C_R07_en_150606_PRT.book Page 26 Wednesday, February 13, 2013 2:47 PM