beautypg.com

Electrical connections – KROHNE OPTISWIRL 4070 EN User Manual

Page 36

background image

4

ELECTRICAL CONNECTIONS

36

OPTISWIRL 4070

www.krohne.com

02/2013 - 4000150606 MA OPTISWIRL4070C R07 en

The pulse output is a passive "open collector" output which is electrically separated from the
current interface and the measuring sensor. It can be configured as a high current output or
NAMUR output using a jumper on the amplifier board.

The maximum frequency of the pulse output is f

max

= 0.5 Hz

The maximum frequency of the pulse output is f

max

= 0.5 Hz

Jumper in NAMUR setting

Jumper in NAMUR setting

Jumper in NAMUR setting

Jumper in NAMUR setting

R

i

= 900 Ω

U

max

= 36 VDC

Jumper in high current setting

Jumper in high current setting

Jumper in high current setting

Jumper in high current setting

Open:

Maximum voltage U

max

= 36 VDC

Closed current I

R

< 1 mA

Closed:

Maximum current I

max

= 100 mA

Voltage U < 2 VDC

Figure 4-4: Jumper settings pulse output

1 Electronic insert
2 Jumper on board
3 Jumper in high current setting
4 Jumper in NAMUR setting