TECHNICAL DATA

8

73

OPTISWIRL 4070

www.krohne.com

02/2013 - 4000150606 MA OPTISWIRL4070C R07 en

Pulse output

Pulse rate

Max. 0.5 pulse/s (corresponds to 1800 pulses/hour)

Power supply

Non-Ex: 24 VDC as NAMUR or open < 1 mA, maximum 36 V, closed 100 mA, U < 2 V

Ex: 24 VDC as NAMUR or open < 1 mA, maximum 30 V, closed 100 mA, U < 2 V

HART

®

HART

®

protocol via current output

Device revision

1

Physical layer

FSK

Device category

Transmitter, galvanically isolated

System requirements

Load min. 250 Ω

Multidrop operation

4 mA

Approvals and certifications

ATEX

ATEX II 2G Ex d ia [ia] IIC T6

FM

Class I, II, III

Div 1/2, groups A-G

MA_OPTISWIRL4070C_R07_en_150606_PRT.book Page 73 Wednesday, February 13, 2013 2:47 PM