Network, Network -26 – Yokogawa Data Acquisition with PID Control CX2000 User Manual
Page 38
2-26
IM04L41B01-65EN
Network
The “Memory Data Out” setting is void on the DX100P/DX200P.
Setting the TCP/IP
1. Click here (also selectable from [Setting] - [System Mode Setting])
2. Select this tab
Set the IP
address
Enter the timeout value when
turned ON
Set these
addresses
when using
the DNS
DNS setting
You must set the DNS, if you are using a host name to specify the destination server of
the file transfer on an FTP client or the server of the e-mail recipient.
Host Name, Domain Name, Domain Suffix: Up to 64 characters
Keep Alive
This function forcibly drops the connection if there are no responses to the test packets
that are sent periodically (every 30 seconds) at the TCP level.
Timeout
This function drops the connection if no data transfer is detected between the PC and the
DXP over a predetermined period of time. This applies to data transfer at the application
level only.
To use this function, select [ON] and enter a time period (1 to 120 min).
Communication Input Available User
Specify a user that uses the communication input data (DX100P: C01 to C12, DX200P:
C01 to C30) from [Admin 1] to[ User 30], and [Serial] (/C2 or /C3 option).
Serial: The communication input data can be used via the serial communication.
Memory Data Out
Select [Ethernet].
2.6 Configuring the System Mode