Display Span
Sets the upper and lower limits of the display.
The range is from –9999999 to 99999999. Set the number of digits to the right the
decimal to four digits or less.
Alarm
You can set up to 4 alarms on each computation channel. The alarm types are upper limit
alarm (H), lower limit alarm (L), delay upper limit alarm (T), and delay lower limit alarm (t).
For details, see section 2.3.
Tag
The settings are the same as the measurement channels. For details, see section 2.3.
TLOG Computation
Timer
Select one of the timers (1 to 3) set in the setup mode.
The computation interval of TLOG computation is set to the time assigned to the selected
timer.
Sum Scale
Set the sum scale.
Rolling Average
Interval
Select the sampling interval when rolling average is activated.
Times (Number of Samples)
Select the number of samples (number of data points used to compute the rolling
average).
Display Zone, Graph, Partial Expansion, and Color
The settings are the same as the measurement channels. For details, see section 2.3.
Copying and Pasting Setup Data
The items checked in [Copy Details] can be copied and pasted.
See the operating procedure, see section 2.3.