Rmh, rms and rml t to o cip implicit assemblies – Watlow EZ-ZONE RUI/Gateway User Manual
Page 58
Watlow EZ-ZONE
®
RUI/Gateway
•
55
•
Appendix
RMH, RMS and RML T to O CIP Implicit Assemblies
Assembly
Members
Assembly
Class, Instance,
Attritbute
RM Module
Data Type
Parameter
Parameter
Class, Instance,
Attritbute
PLC
Data Type
0
Cannot be changed
Binary
Device Status
none
DINT
1
0x77, 0x02, 0x01
DINT
None specified
- - - -
- - - -
2
0x77, 0x02, 0x02
DINT
None specified
- - - -
- - - -
3
0x77, 0x02, 0x03
DINT
None specified
- - - -
- - - -
4
0x77, 0x02, 0x04
DINT
None specified
- - - -
- - - -
5
0x77, 0x02, 0x05
DINT
None specified
- - - -
- - - -
6
0x77, 0x02, 0x06
DINT
None specified
- - - -
- - - -
7
0x77, 0x02, 0x07
DINT
None specified
- - - -
- - - -
8
0x77, 0x02, 0x08
DINT
None specified
- - - -
- - - -
9
0x77, 0x02, 0x09
DINT
None specified
- - - -
- - - -
10
0x77, 0x02, 0x0A
DINT
None specified
- - - -
- - - -
11
0x77, 0x02, 0x0B
DINT
None specified
- - - -
- - - -
12
0x77, 0x02, 0x0C
DINT
None specified
- - - -
- - - -
13
0x77, 0x02, 0x0D
DINT
None specified
- - - -
- - - -
14
0x77, 0x02, 0x0E
DINT
None specified
- - - -
- - - -
15
0x77, 0x02, 0x0F
DINT
None specified
- - - -
- - - -
16
0x77, 0x02, 0x10
DINT
None specified
- - - -
- - - -
17
0x77, 0x02, 0x11
DINT
None specified
- - - -
- - - -
18
0x77, 0x02, 0x12
DINT
None specified
- - - -
- - - -
19
0x77, 0x02, 0x13
DINT
None specified
- - - -
- - - -
20
0x77, 0x02, 0x14
DINT
None specified
- - - -
- - - -
21
0x77, 0x02, 0x15
DINT
None specified
- - - -
- - - -
22
0x77, 0x02, 0x16
DINT
None specified
- - - -
- - - -
23
0x77, 0x02, 0x17
DINT
None specified
- - - -
- - - -
24
0x77, 0x02, 0x18
DINT
None specified
- - - -
- - - -
25
0x77, 0x02, 0x19
DINT
None specified
- - - -
- - - -
26
0x77, 0x02, 0x1A
DINT
None specified
- - - -
- - - -
27
0x77, 0x02, 0x1B
DINT
None specified
- - - -
- - - -
28
0x77, 0x02, 0x1C
DINT
None specified
- - - -
- - - -
29
0x77, 0x02, 0x1D
DINT
None specified
- - - -
- - - -
30
0x77, 0x02, 0x1E
DINT
None specified
- - - -
- - - -
31
0x77, 0x02, 0x1F
DINT
None specified
- - - -
- - - -
32
0x77, 0x02, 0x20
DINT
None specified
- - - -
- - - -
33
0x77, 0x02, 0x21
DINT
None specified
- - - -
- - - -
34
0x77, 0x02, 0x22
DINT
None specified
- - - -
- - - -
35
0x77, 0x02, 0x23
DINT
None specified
- - - -
- - - -
36
0x77, 0x02, 0x24
DINT
None specified
- - - -
- - - -
37
0x77, 0x02, 0x25
DINT
None specified
- - - -
- - - -
38
0x77, 0x02, 0x26
DINT
None specified
- - - -
- - - -
39
0x77, 0x02, 0x27
DINT
None specified
- - - -
- - - -
40
0x77, 0x02, 0x28
DINT
None specified
- - - -
- - - -
CIP Implicit Assembly
Target (
RMH
/
RMS
/
RML
) to Originator (Master)
Note:
When configuring the gateway T to O assembly size for the RMH, RMS and RML, the maximum size using
the RUI is 20. The graphic above shows 41 members where the first member (0 - Device Status) is implied.
When configuring the Master assembly size, Device Status cannot be omitted.