Chapter 3 Keys and Displays

Infinity Key ˆ

In the Home Page, press

to scroll through the net-

work zones, clears alarms

and errors if clearable.
On other pages, press

to back up one level, or

press and hold for two

seconds to return to the

Home Page.

Advance Key

Advances through pa-

rameter prompts.

®

Temperature Units:

Indicates whether the tem-

perature is displayed in Fahr-

enheit or Celsius.

Output Activity:

Number LEDs indicate activ-

ity of outputs. A flashing light

indicates output activity.

Percent Units:

Lights when the controller is

displaying values as a percent-

age or when the open-loop set

point is displayed.

Profile Activity;

Lights when a profile is run-

ning. Flashes when a profile is

paused.

Communications Activity

Flashes when another device is

communicating with the RUI.

Up and Down Keys ¿ ¯

In the Home Page, the param-

eter specified by Custom 1 in

the factory page. In other pag-

es, changes the upper display

to a higher or lower value, or

changes a parameter selection.

Chapter 3: Keys and Displays

3

Upper Display:

In the Home Page, displays
the parameter specified by
Custom 1 in the factory page,
otherwise displays the value
of the parameter in the lower
display.

Zone Display:

Indicates the controller zone

that the RUI is currently

communicating with.

A = zone 10

E = zone 14

b = zone 11

F = zone 15

C = zone 12

h = zone 16

d = zone 13

J = zone 17

Lower Display:

Indicates the set point or

output power value during

operation, or the parameter

whose value appears in the

upper display.

EZ Key:

This key can be programmed

to do various tasks, such as

starting a profile.

Responding to a Displayed Message
Attention Codes

An active message will cause the display to toggle be-

tween the normal settings and the active message in

the upper display and Attention [Attn] in the lower

display.

Your response will depend on the message and the

controller settings. Some messages, such as Ramp-

ing and Tuning, indicate that a process is underway.

If the message was generated by a latched alarm or

limit condition, the message can be cleared when the

condition no longer exists by simply pushing the In-

finity ˆ key or alternatively, by following the steps

below. If an alarm has silencing enabled, it can also

be silenced.

Push the Advance Key

to display Ignore [ignr]

in the upper display and the message source, such

as Limit High [Li;h1] in the lower display. Use the

Up ¿ and Down ¯ keys to scroll through possible

responses, such as Clear [`CLr] or Silence [`SiL],

then push the Advance

or Infinity ˆ key to ex-

ecute the action. See the table below for further infor-

mation on the Attention Codes.

Note:

Upon power up, the up-

per or left display will

briefly indicate the firm-

ware revision and the

lower or right display will

show RUI.