3 setting up a petrainer exerciser, 3 setting up a pe trainer exerciser – Teledyne LeCroy PETracer EML Analyzer and Exerciser User Manual User Manual
Page 38

Chapter 3: Installation
PETracer EML User Manual
30
LeCroy Corporation
3.3 Setting Up a PETrainer Exerciser
Step 1 Remove the Exerciser and UPAS from its shipping container. The
PETracer EML module is already installed in the UPAS.
Step 2 Connect the Exerciser to a 100-volt to 240-volt, 50 Hz to 60 Hz, 120 W
power outlet using the provided power cord.
Note: The Exerciser is capable of supporting supply voltages between 100-volt
and 240-volt, 50 Hz or 60 Hz, thus supporting all known supply voltages around
the world.
Step 3 Connect the USB cable between the USB port on the back of the UPAS
and a USB port on the PC.
Note: All hardware and cables should be setup prior to power-up.
Install Device Emulator or Host Emulator as described in the previous sections.
Also install any cables between the Emulator and PETrainer EML Exerciser as
described in the previous sections.
Step 4 Turn on the power switch on the rear of the UPAS.
Note: At power-on, the Exerciser initializes itself in approximately five seconds
and performs an exhaustive self-diagnostic that lasts about fifteen seconds. The
Status LED of the UPAS base unit turns red on power up/initialization. The LED
remains on approximately 20 seconds while the Exerciser performs
self-diagnostic testing. If the diagnostics fail, the Status LED blinks red, indicating
a hardware failure. If this occurs, call LeCroy Customer Support for assistance.
Step 5 Follow on-screen Plug-and-Play instructions for the automatic
installation of the Exerciser as a USB device on the Host PC (the
required USB files are included on the CD). Step through the Windows
®
hardware wizard. If the wizard prompts you for driver information, point
it to the CD which should be in your disk drive.
The host operating system detects the Exerciser and begins to install the USB
driver.