Teledyne LeCroy WaveJet 300A Series Remote Control User Manual
Page 44
WaveJet 300A Series
44
917976 Rev A
Status TESE
Command/Query
DESCRIPTION The
TESE
command
sets the trigger event status enable
register. In other words, it determines whether the
summary message of the trigger event status register
is connected to the status byte. The TESE? query reads
the current setting of the trigger event status enable
register.
COMMAND SYNTAX
TESE
QUERY SYNTAX
TESE?
RESPONSE FORMAT
The current setting of the trigger event status enable
register is identified in
The format is
Status TESR?
Query
DESCRIPTION
The TESR? query reads the trigger event status
register. In other words, it determines whether a
single measurement is completed. After the status is
read, the contents of the register are cleared.
COMMAND SYNTAX
QUERY SYNTAX
TESR?
RESPONSE FORMAT
Each bit of the trigger event status register is
weighted by a power of 2. The format is
Trigger THTM
Command/Query
DESCRIPTION The
THTM command defines the trigger hold-off time. The
THTM? query returns the defined trigger hold-off time.
COMMAND SYNTAX
THTM
is used, and the suffix is also valid.
Available range is 0 to 50.0 s.
If specified holdoff is < 200 ns, the trigger hold-off
is turned off.
QUERY SYNTAX
THTM?
RESPONSE FORMAT
The currently set hold-off time is identified in
"OFF", 0 is input to
REMARKS
THTM command reports device-specific error (DDE) when
TTYP is not EDGE..