Status *OPC
Command/Query
DESCRIPTION
The *OPC (Operation Complete) command sets the OPC bit
(bit 0) of the standard event status register (ESR) to
"1" when all the preceding operations are completed.
Since the *OPC? query issues the response after
execution of all preceding commands, "1" is returned.
For the *OPC? query, the OPC bit (bit 0) of the ESR
register is not affected by other operations.
COMMAND SYNTAX
*OPC
QUERY SYNTAX
*OPC?
RESPONSE FORMAT
1
DISPLAY PERS
Command/Query
DESCRIPTION
The PERS command sets persistence display time. The
PERS? query returns the current persistence display
time.
COMMAND SYNTAX
PERS
QUERY SYNTAX
PERS?
RESPONSE FORMAT
Vertical PROBE
Command/Query
DESCRIPTION
The PROBE command sets the probe ratio of the specified
input channel. AUTO, 1, 10, 20, 100, 200, 1000, or 2000
can be selected. The PROBE? query returns the selected
probe ratio.
COMMAND SYNTAX
: = {C1, C2} (WJ352/332/322/312)
For the combination and meaning of set items in
"Remarks".
QUERY SYNTAX