Page 78
-78/85-
6. Precautions
6-1.
Handling Position Data and Programs
The number of positions and the number of programs than can be handled by each controller differ (refer to Table 6-1). When
handling position data and programs, please follow the three items below. However, [1] is not required if the models to be
supported can be identified.
[1] Determine the number of positions and the number of programs that can be handled by the controller from the
controller’s model code and unit code (for details, refer to 6-1-1).
[2] Use position data query and change messages distinguishably between the controller with extended data and the
controller without extended data (for details, refer to 6-1-2).
[3] If the controller with extended data will handle all data, send the controller function specification 2 (271h) command at
the start of communication (for details, refer to 6-1-3).
Table 6-1
Model Code
Unit Code
No. of Positions
No. of Programs
Extended
Data
X-SEL-J/K B8
-
3000
64
No
S-SEL-JX/KX C0
-
3000
64
No
TT BC
-
3000
64
No
X-SEL-P/Q
FROM 16M version
BA
71
4000
64
No
FROM 32M version
72
20000
(4000)
128
(64)
Yes
X-SEL-PX/QX
FROM 16M version
C2
71 4000
64
No
FROM 32M version
72
20000
(4000)
128
(64)
Yes
SSEL
SRAM 4M version
D6
72
1500
64
No
SRAM 16M version
72
20000
(1500)
128
(64)
Yes
ASEL D0
-
1500
64
No
PSEL D3
-
1500
64
No
X-SEL-R/S/RX/SX/R
XD/SXD
1-axis specification
BB (R//S)
C3 (RX/SX)
C5 (RXD/SXD)
-
53332
128 No
2-axis specification
40000
3-axis specification
32000
4-axis specification
26666
5-axis specification
22856
6-axis specification
20000
7-axis specification
17776
8-axis specification
16000
TTA BD
-
30000
256
No
* Numbers in ( ) indicate the numbers of data that can be handled before sending the controller function specification 2 (271h)
command.
* X-SEL-J/K/JX/KX/R/S/RX/SX/RXD/SXD, TT, TTA, ASEL/PSEL can be determined solely from the model code.