IAI America TTA User Manual
Page 54
-54/85-
4-3-36. Software
Reset
(25BH)
Function: Reset the software.
Data name
Data range (value)
Data size
[bytes]
Cumulative
bytes [bytes]
Endian Sign
extension
Unit
Description Remarks
Big Little Yes No
Command
Header '!'
1
1
Station 'XX(h)'
2
3
Message ID
'25B(h)'
3
6
SC 'XX(h)'
2
8
CR 0Dh
1
9
LF 0Ah
1
10
Normal response
0
0
No normal response.
* Because the controller transits to initialization
processing after transmitting this command, no
communication can be established during this
period. (The initialization processing time
depends on the model, installed options, etc.)
Perform communication recovery on the
master station (host), such as resuming retry
transmission after waiting for a certain period.
Error
respon
se
Error response
format
Refer to the error
response format.
10 10
(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is
added before the closing quotation mark.