4-3-28. Positon Data Clear (Old: Point Data Clear) (246H)
Function: Clear position data for the number of clear positions from the clear start position number. (Position data comments cannot be cleared.)
Data name
Data range (value)
Data size
[bytes]
Cumulative
bytes [bytes]
Endian Sign
extension
Unit
Description Remarks
Big Little Yes No
Command
Header '!'
1
1
Station 'XX(h)'
2
3
Message ID
'246(h)'
3
6
Clear start position
data number
'XXX(h)' 3 9
Number of clear
position data
'XXX(h)' 3 12
SC 'XX(h)'
2
14
CR 0Dh
1
15
LF 0Ah
1
16
Normal
response
Header '#'
1
1
Station 'XX(h)'
2
3
Message ID
'246(h)'
3
6
SC 'XX(h)'
2
8
CR 0Dh
1
9
LF 0Ah
1
10
Error
respon
se
Error response
format
Refer to the error
response format.
10 10
(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is
added before the closing quotation mark.