IAI America TTA User Manual
Page 43
-43/85-
4-3-25. Operation
Stop & Cancel (238H)
Function: Stop/cancel the operation (including servo command/output cancellation while interlock is on hold)
Data name
Data range (value)
Data size
[bytes]
Cumulative
bytes [bytes]
Endian Sign
extension
Unit
Description Remarks
Big Little Yes No
Command
Header '!'
1
1
Station 'XX(h)'
2
3
Message ID
'238(h)'
3
6
Stop axis pattern
'XX(h)'
2
8
* Including servo command cancellation while
interlock is on hold
Appended command
byte
'XX(h)' 2 10
Bit 1 to 7 (Reserved for system use)
Bit 0 (Specification of output cancellation during
interlock on-hold (OUT port) (when all operations
are paused)): 0 = Not canceled / 1 = Canceled
tentatively
SC 'XX(h)'
2
12
CR 0Dh
1
13
LF 0Ah
1
14
Normal
response
Header '#'
1
1
Station 'XX(h)'
2
3
Message ID
'238(h)'
3
6
SC 'XX(h)'
2
8
CR 0Dh
1
9
LF 0Ah
1
10
Error
respon
se
Error response
format
Refer to the error
response format.
10 10
(Note 1) Add H (or h) at the end of each data expressed in hexadecimal notation. If there is no H or h at the end, the data is considered a decimal.
(Note 2) Data enclosed in single quotation marks indicates an ASCII code. Data is a hexadecimal ASCII code if (h) is added before the closing quotation mark, or a decimal ASCII code if (d) is
added before the closing quotation mark.