CompoNet

2.8 I/O

Signal

Timings

When any of the control signal is turned ON to perform the operation of the robot cylinder using the PLC's
sequence program, the response (status) is returned to the PLC. The maximum response time is expressed
using the following formula.

Maximum response time (msec)

ዙYt+xt+3+ command processing time (operation time, etc.)

Yt: Master Station

ψslave transmission delay time

xt: Slave

ψMaster Station Transmission Delay Time


Master Station

ψ For the master station -> slave transmission delay (Yt) and slave o master station

transmission delay (xt), refer to the Operation Manuals for the CompoNet master unit and
PLC installed in the master unit.

















Filed Network Transmission
Delay Time

PLC sequence program

Control Signal

Status Signal

Control Signal

Status Signal

Slave

Transmission delay time (Yt)

Slave
Transmission delay time (Xt)

Command processing time

Master station

Master station