IAI America PCON-CFA User Manual
Page 26
2. ACON-C/CG,
PCON-C/CG
20
CompoNet
x ACON/PCON outputoPLC Input Side (* “n” shows the node address of each axis.)
DO on the ACON or PCON side and Output Data Register
Remote I/O Mode
Position / Simplified
Direct Value Mode
Half Direct Value
Mode
Full Direct Value
Mode
Remote I/O Mode 2
PLC input area
(CH)
Number of occupied
channels:1CH
Number of occupied
channels:4CH
Number of occupied
channels:8CH
Number of occupied
channels:16CH
Number of occupied
channels:6CH
n
Port No.0 to 15
Port No.0 to 15
n
1
Target Position
Target Position
Target Position
Occupied area
n
2
Completed Position
No.
(simple alarm ID)
n
3 Status
Signal
Command Current
Command Current
Target Position
n
4
n
5
Current Speed
Current Speed
Command Current
n
6
Alarm Code
Alarm Code
n
7 Status
Signal
n
8
n
9
n
10
n
11
n
12
n
13
n
14
Occupied area
n
15
Status Signal
(Note) The Occupied area shows the area to be occupied with the operation mode setting.
Therefore, this area cannot be used for any other purpose. Also, exercise caution to avoid node address
duplication.