beautypg.com

IAI America PCON-CFA User Manual

Page 148

background image

3. SCON-CA/CF

A


142

CompoNet

(

30) Stop Mode Selection (ASO1, ASO0) PLC output signal


Select the stop mode for the duration before the movement to the next position after a positioning is
completed.
If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power
consumption.
Refer to the operation manual for the controller for more information.

ASO1 ASO0

Functions

Reference

OFF

OFF

Disabled

Set in delivery

OFF ON

Automatic Servo OFF Method
Parameter No. 36 is valid for T

ON OFF

Automatic Servo OFF Method
Parameter No. 37 is valid for T

ON ON

Automatic Servo OFF Method
Parameter No. 38 is valid for T

F C

)CC

5 F

)

'?

F@

5 F1

)

6@ 2E

6

6%9@C E ?> E FE

+ 0*> BE

E@E?C

-C?E F


(31) Light error status (ALML)

This becomes 1 when a message level (light alarm that the operation can be kept on) is generated.
This signal is not linked with ALM_LED on the front panel of the controller.
[Refer to the instruction manual for the controller main body for the details of the alarms.]

PLC input Signal

This manual is related to the following products: