IAI America PCON-CFA User Manual
Page 148
3. SCON-CA/CF
A
142
CompoNet
(
30) Stop Mode Selection (ASO1, ASO0) PLC output signal
Select the stop mode for the duration before the movement to the next position after a positioning is
completed.
If the duration for a stop is long, the system automatically turns the servo OFF to reduce the power
consumption.
Refer to the operation manual for the controller for more information.
ASO1 ASO0
Functions
Reference
OFF
OFF
Disabled
Set in delivery
OFF ON
Automatic Servo OFF Method
Parameter No. 36 is valid for T
ON OFF
Automatic Servo OFF Method
Parameter No. 37 is valid for T
ON ON
Automatic Servo OFF Method
Parameter No. 38 is valid for T
F C
)CC
5 F
)
'?
F@
5 F1
)
6@ 2E
6
6%9@C E ?> E FE
+ 0*> BE
E@E?C
-C?E F
(31) Light error status (ALML)
This becomes 1 when a message level (light alarm that the operation can be kept on) is generated.
This signal is not linked with ALM_LED on the front panel of the controller.
[Refer to the instruction manual for the controller main body for the details of the alarms.]
PLC input Signal