IAI America PCON-CFA User Manual
Page 214
4. SCON-CA
208
CompoNet
PLC input
Channel (* “n” shows the node address of each axis.)
1 word (1CH) = 16 bits
(lower word)
Current Position
(upper word)
Current Position
When the target position is shown using the negative figure, it is expressed using the
complement of 2.
Completed
Position No.
n
3
b15 b14 b13 b12 b11 b10
b9
b8
b7
b6
b5
b4
b3
b2 b1 b0
Status signal
EMGS
PWR
CEN
D
ZONE1
PZONE/
ZONE2
LOAD
TRQS
RMDS
BALM
PU
SHS
PSFL
SV
ALM
MOVE
HEN
D
PEND