Instruction for Cable Track Type Wiring
Drawing No.
GMM12-001
1/1
Cable track specification
Option model code
CTM CTL CTXL
Cable track model code
TKP0450W58
TKP0450W78
TKP0450W108
Cable track specification
Option model code
CT
Cable track model code
TKP0450W38
The parts content should be the same for the both cable tracks between X and Y and between Y and Z.
However, for the construction with no connector box on the moving end, the same cable clamp as one on the
fixed end should also be used on the moving end.
Cable track
TKP0450W38
M6 ×12 hex socket head cap screw (4pcs)
M6 × 10 hex socket head cap screw (4pcs)
M6 plain washer (2pcs)
M6 plain washer
(4pcs)
M3 × 5 hex socket head cap screw (2pcs)
Connector box
(the type with
φ4 hole added)
1080755*:
cable clamp 3
1080753*:
cable clamp 1
M6 hexagon nut (4pcs)
M6 hexagon nut
(4pcs)
Installation of cable track
Cable Wiring and Fixation
Cable band
Cable band
Put a cable band through the comb teeth and the hole, and affix the cables in a pair.
Guide rail
For the type of X axis SMX (BA** Type),
the parts on area is as shown below.
• M6 × 10 hex socket head cap screw (2pcs)
• M6 × 8 hex socket head cap screw (2pcs)
• No M6 plain washer
(Moving end)
(Fixed end)
Installation of cable track
Cable Wiring and Fixation
Put a cable band through the holes, and affix the cables in a pair.
(Same as W38 on the moving end)
Cable band
Cable track
TKP0450W58/W78/W108
M6 × 12 hex socket head cap screw (4pcs)
M6 plain washer (4pcs)
M6 hexagon nut (4pcs)
M6 × 10 hex socket head cap screw (2pcs)
M3 × 5 hex socket head cap screw (2pcs)
Connector box
(the type with
φ4 hole added)
1080755*:
cable clamp 3
1080754*:
cable clamp 2
M6 hexagon nut (4pcs)
For the type of X axis SMX (BA** Type),
the parts on area is as shown below.
• M6 × 8 hex socket head cap screw (2pcs)
• No M6 plain washer
M6 × 10 hex socket head cap screw (2pcs)
M6 plain washer (2pcs)
(Fixed end)
Caution
• Avoid piling up a cable onto another or have cables running across each other, and
have the cables laid out straight in parallel.
• Basically, M cables and PG cables should be separated in each bunch.
• When affixing the cables on the moving end and fixed end, gather the cables on the
inner side of the cable track, and have enough play on the cables that would not
apply tension to them when the cable track is moved for the swing stroke.
Also, make sure the cables are not twisted.