Archive, Evolver 202 robotic atomizers - safety – Ransburg Evolver 202 Solvent A11918-XXX User Manual
Page 7

AA-07-01
AREA
AREA
AREA
AREA
AREA
Tells where hazards
may occur.
HAZARD
HAZARD
HAZARD
HAZARD
HAZARD
Tells what the hazard is.
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
SAFEGUARDS
Tells how to avoid the hazard.
Spray Area
Spray Area
Spray Area
Spray Area
Spray Area
Improper operation or mainte-
nance may create a hazard.
Personnel must be properly
trained in the use of this equip-
ment.
Personnel must be given training in accordance with
the requirements of NFPA-33.
Instructions and safety precautions must be read and
understood prior to using this equipment.
Comply with appropriate local, state, and national
codes governing ventilation, fire protection, operation
maintenance, and housekeeping. Reference OSHA,
NFPA-33, and your insurance company requirements.
General Use and
General Use and
General Use and
General Use and
General Use and
Maintenance
Maintenance
Maintenance
Maintenance
Maintenance
Fire Hazard
Improper or inadequate oper-
ation and maintenance proced-
ures will cause a fire hazard.
Protection against inadvertent
arcing that is capable of
causing fire or explosion is
lost if any safety interlocks
are disabled during operation.
Frequent power supply shut-
down indicates a problem in
the system requiring correc-
tion.
Fire extinguishing equipment must be present in the
spray area and tested periodically.
Spray areas must be kept clean to prevent the accu-
mulation of combustible residues.
Smoking must never be allowed in the spray area.
The high voltage supplied to the atomizer must be
turned off prior to cleaning, flushing or maintenance.
When using solvents for cleaning:
Those used for equipment flushing should have flash
points equal to or higher than those of the coating
material.
Those used for general cleaning must have flash
points above 100
°F (37.8°C).
Spray booth ventilation must be kept at the rates
required by local and/or country codes. In addition,
ventilation must be maintained during cleaning opera-
tions using flammable or combustible solvents.
Electrostatic arcing must be prevented.
Test only in areas free of combustible material.
Testing may require high voltage to be on, but only as
instructed.
Non-factory replacement parts or unauthorized equip-
ment modifications may cause fire or injury.
If used, the key switch bypass is intended for use only
during set-up operations. Production should never be
done with safety interlocks disabled.
The paint process and equipment should be set up and
operated in accordance with local and/or country safety
codes.