Evolver 202 Robotic Atomizers - Maintenance

Low V

Low V

Low V

Low V

Low Voltage Cable Removal

oltage Cable Removal

oltage Cable Removal

oltage Cable Removal

oltage Cable Removal

(Refer to Figure 14)

(Refer to Figure 14)

(Refer to Figure 14)

(Refer to Figure 14)

(Refer to Figure 14)

1. Disconnect low voltage cable [2] from rear of
power supply. For A10406-XX power supply,
disconnect circular connector from receptacle on
rear of power supply. For LECU5004-XX power
supply, disconnect wires from connector J3 at
rear of MicroPak.

2. Loosen retaining ring [6] (see Figure 12) and
remove applicator from robot wrist.

3. Using 3/16" Allen wrench, remove set screw
[10].

4. Remove the low voltage cable [2] by pulling
through the robot arm and mounting plate.

5. To reinstall, insert power supply end of cable [2]
through mounting plate [3], pull through robot arm
and connect to junction box or power supply. For
connections to power supply, plug connector into
receptacle (A10406-XX power supply) or connect
wires as shown in Figure 4 (LECU5004-XX power
supply).

6. Align the timing mark of the plug on the appli-
cator end of the cable [2] with the mark on the
mounting plate [3] and tighten set screw [10].