Archive, Applica, Low vol – Ransburg Evolver 202 Solvent A11918-XXX User Manual
Page 23
![background image](/manuals/348164/23/background.png)
AA-07-01
1 8
1 8
1 8
1 8
1 8
Evolver 202 Robotic Atomizers - Installation
APPLICA
APPLICA
APPLICA
APPLICA
APPLICAT
T
T
T
TOR AND
OR AND
OR AND
OR AND
OR AND
MANIFOLD ASSEMBL
MANIFOLD ASSEMBL
MANIFOLD ASSEMBL
MANIFOLD ASSEMBL
MANIFOLD ASSEMBLY
Y
Y
Y
Y
(See Figures 4, 5, and 6)
(See Figures 4, 5, and 6)
(See Figures 4, 5, and 6)
(See Figures 4, 5, and 6)
(See Figures 4, 5, and 6)
The tubing, hose, and low voltage cable come
bundled from the factory. Pull the bundle through
the robot spacer plate and robot wrist carefully to
prevent any cuts on the cable or hoses. Use the
six (6) socket head cap screws (76566-24C)
included with the rear manifold tubing assembly to
attach the rear manifold assembly (79106 or
A10892) to the robot spacer plate (see Table 1).
Connect each signal line as required per "Signal
Identification Tables (English and Metric) Tubing
Bundles" in the "Installation" section.
Robot Spacer Plate
Robot Spacer Plate
Robot Spacer Plate
Robot Spacer Plate
Robot Spacer Plate
The robot spacer plate is included with the robot
manifold assembly to increase life of the tubing
bundle. The extra spacing it provides increases
the bend radius of the tubes and decreases the
hose or cable stress at the connector.
There is only one way the spacer plate may be
assembled to the mounting plate. The spacer
plate has an alignment pin that may only engage
in one hole position in the robot mount plate. This
provides the final position to top dead center of the
robot.
Six robot spacer plates shown in Table 1 are
available for this product.
LOW VOL
LOW VOL
LOW VOL
LOW VOL
LOW VOLT
T
T
T
TAGE CABLE
AGE CABLE
AGE CABLE
AGE CABLE
AGE CABLE
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATIONS
TIONS
TIONS
TIONS
TIONS
For installations utilizing the LECU5004-XX
MicroPak power supply, connect the low voltage
cable (79008-XX) from the robot manifold assembly
to the LECU5004-XX MicroPak controller or
junction box. If connecting to a junction box, use
a junction cable (77062-XX) to make the connection
from the junction box to the LECU5004-XX
MicroPak. Make connections as shown in Figure
4.
For installations utilizing the A10406-XX Evolver
MicroPak power supply, connect the low voltage
cable (A11353-XX or A11356-XX) from the robot
manifold assembly or junction box to the receptacle
on the rear of the A10406-XX power supply. To
maintain FM Approval, this cable must be secured
to the stress relief bar on the rear of the power
supply. (See A10406-XX Evolver MicroPak
Power Supply manual for further information on
connecting the low voltage cable.)
>
If the length of the fan or atomization
air lines exceeds 30 ft. (10m), the lines
must be upsized to 1/2" ID (12mm for
metric).
N O T E
N O T E
N O T E
N O T E
N O T E
>
For the dipswitch settings for the
Evolver 202, reference the current
MicroPak service manual.
N O T E
N O T E
N O T E
N O T E
N O T E
>
Leave 12-24 inches (.30m-.61m) of
extra length on all lines to prevent ex-
treme tension being applied to these lines
during robot movement. This increases
tubing bundle life.
N O T E
N O T E
N O T E
N O T E
N O T E
79107-00
ABB Robots
78983-00
Fanuc P155, 145 Robots
79131-00
Fanuc P200 Robot
A10847-00
Adapter (Kawasaki-KE610L)
A10848-00
Adapter (Motoman-PX2850)
A10849-00
Adapter (Motoman-PX2900)
A10851-00
Adapter (B & M-LZ2000)
Part #
Part #
Part #
Part #
Part #
Description
Description
Description
Description
Description
T
T
T
T
TABLE 1 - SP
ABLE 1 - SP
ABLE 1 - SP
ABLE 1 - SP
ABLE 1 - SPACER PLA
ACER PLA
ACER PLA
ACER PLA
ACER PLATES
TES
TES
TES
TES
ARCHIVE