Ransburg, Fluid tube coils (separate sales parts only), Table c - fluid tube coils – Ransburg RMA Dual Purge Direct A12300 User Manual
Page 88: Replacement fitting and ferrules

RMA-303 Dual Purge/Direct Charge - Parts Identification
83
Fluid Tube Coils
(Separate Sales Parts Only)
If purchasing spare parts, they must be modified
as explained.
To ensure proper sealing and holding, the fittings
require that the ends of the fluid coils have a
groove cut into them as shown. Use groove cut-
ter A11567-00, by sliding the end of the tool over
the tubing until it bottoms out. Hold the tubing in
one hand and the tool in the other. Make three
complete revolutions of the tool on the tubing in
the direction of the arrow stamped on the tool. To
remove the tool, hold the tube and the main body
of the tool with one hand, slide the rear portion
of the tool back until it stops. Pull out the tubing
from the end of the tool. By pulling back the rear
portion of the tool, it relieves the pressure of the
.25" OD X .125" ID for Highly Resistive Materials (Clear Coat)
.25" OD X .170" ID for Conductive Materials (Base / Clear)
.25" OD X .125" ID for Highly Conductive Materials (Base / Clear)
TABLE C - Fluid Tube Coils
01
02
03
Dash
No.
Description
77531-00
77517-00
78450-00
"C"
Figure 58: Fluid Tube Coils
cutting edge off of the tubing before sliding it out.
Trim off ends to dimensions shown. End should
be cut off square. Slide the fitting and ferrules
onto the tube as shown. The tapered ferrule must
go past the newly cut groove to properly lock into
place when installed. Install hand tight and then
1/4-1/2 turn more with a 9/16" end wrench or flare
nut wrench.
Fluid Fitting
Front Ferrule
Rear Ferrule
Replacement Fitting and Ferrules
78449-00
EMF-203-04
EMF-202-04
Part #
Description
Ransburg
LN-9263-08.5
1/8"
1/8"
1/8"
1/8"