beautypg.com

Ransburg, Rma-303 dual purge/direct charge - maintenance – Ransburg RMA Dual Purge Direct A12300 User Manual

Page 79

background image

RMA-303 Dual Purge/Direct Charge - Maintenance

74

†

Always use a torque wrench to torque

the seats in place. Over-torquing the seats

may cause permanent irrepairable damage

to the rear manifold.

C A U T I O N

!

Lubricate the valve o-rings with a suitable o-ring

lubricant. By hand, start the threads clockwise

into the pocket. Tighten using a 1/2" (13mm)

socket and torque to 15-20 lbs•in (1.7-2.3 Nm)

after value is down.

Figure 50: Valve Torque

Support Rod, Fluid Coil, Cup Wash

Line Removal/Replacement

Support Rod, Fluid Coil, Cup Wash Re-

moval

Using wrench (A11284-00), remove each of the

support rods. Each is removed by turning count-

er-clockwise.

Figure 51: Support Rod Removal

Remove external cup wash line by unscrewing

the solvent fitting. Remove cup wash connection

line by removing the solvent fitting and ferrules.

Remove the coiled tube assembly by removing

the fluid fitting in a counter-clockwise direction.

Figure 52: Fluid/Cup Wash Line Removal

Ransburg

LN-9263-08.5

EXTERNAL CUP

WASH LINE

SOLVENT

FITTING AND

FERRULE

SOLVENT FITTING

AND FERRULE

CUP WASH

CONNECTION LINE

COILED FLUID TUBE

FLUID FITTING,

UPPER AND LOWER

FERRULE

KNUCKLE