AIR FILTRATION REQUIREMENTS

Filter Model No.

HAF-503

RPM-417

RPM-418

HAF-15 Element,

One

RPM-32 Elements,

Carton of 4

RPM-33 Elements,

Carton of 8

Pre-filter, removes coarse amounts of oil, moisture & dirt.

Used upstream of RPM-417 pre-filter (used in systems

with poor air quality).

Pre-filter, coalescing type, 136 SCFM, 98.5% efficiency

particulate removal .3 to .6 micron, max. aerosol passed

1.0 micron, max. solid passed .4 micron (dependent upon

scfm requirement per applicator, one RPM-417 can be

used with up to three RMA-303 assemblies).

Bearing air filter, coalescing type, 19 SCFM, 99.995% ef-

ficiency particulate removal .3 to .6 micron, max. aerosol

passed .6 micron, max. solid passed .2 micron (one per

applicator).

Description / Specifications

Replacement

Element Part No.

RMA-303 Dual Purge/Direct Charge - Installation

35

Ransburg

LN-9263-08.5

†

Air must be properly filtered to ensure

extended turbine life and to prevent con-

tamination of the paint finish. Air which

is not adequately filtered will foul the tur-

bine air bearings and cause premature

turbine failure. The correct type of filters

must be used in an RMA-303 system.

The filter elements must be replaced on

a regular schedule to assure clean air.

†

It is the end user’s responsibility

to ensure clean air at all times. Turbine

failure resulting from contaminated

air will not be covered under warranty.

†

"Air Filtration Requirements" shows the

pre-filter(s) and bearing air filter which are

recommended for use in RMA-303 systems.

If other filters are incorporated in the system,

the filters to be used must have filtering capac-

ities equal or better than those shown in the

"Air Filtration Requirements" in this section.

†

The user must ensure the bearing air

supply is not inadvertently turned off while

the RMA-303 air motor is turning. This will

cause air bearing failure.

C A U T I O N

!

NOTE

†

Each applicator must have its own filter

for bearing air. Recommended: RPM-418