beautypg.com

Ransburg, Rma-303 dual purge/direct charge - maintenance, Fiber optic cable removal/ replacement – Ransburg RMA Dual Purge Direct A12300 User Manual

Page 80: Turbine o-ring replacement (figure 534)

background image

RMA-303 Dual Purge/Direct Charge - Maintenance

75

Fiber Optic Cable Removal/

Replacement

Fiber Optic Cable Removal

Remove the fiber optic nut and fitting from the

knuckle. Loosen the fiber optic transmitter using

the removal tool (78279-00) on the fiber optic nut.

Push while twisting on the fiber optic cable from

the cascade side of the knuckle until the connector

nut (black) of the transmitter is visible. Loosen

the connection nut and pull the fiber optic cable

Figure 53: Fiber Optic Transmitter Removal

out of the cascade side of the knuckle.

Fiber Optic Cable Replacement

Slide the tube fitting, nut, and o-ring over the cable.

Push the bare cable end of the fiber optic cables

through the knuckle hole, cascade side. Push the

cable far enough through the knuckle to connect

the fitting of the fiber optic transmitter to the cable

end. Gently pull the fiber optic transmitter into the

hole. Slide the retaining nut over the transmitter

and tighten clockwise using removal tool (78279-

00). Install the fitting into the cascade side of the

knuckle. Slide the o-ring and nut toward the fitting

and tighten the nut in place (snug).

Turbine O-Ring Replacement

(Figure 534)

Remove air bearing turbine from the atomizer.

Remove all exterior o-rings.

Lightly lubricate all o-rings with A11545 Petrolatum

jell before reinstalling.

O-ring Kit A11534-00 contains all required o-rings

for replacement.

Support Rod, Fluid Coil, Cup Wash Re-

placement

Attach the cup wash connection line in the knuckle

and tighten the fitting and ferrule clockwise hand

tight. Then tighten 1/8-1/4 turn more with a wrench.

Attach the fluid coil, upper and lower ferrule to

the knuckle. Attach the external cup wash line

by installing the solvent fitting and ferrule on the

turbine side of the knuckle. Tighten nut on fluid coil

by hand until stop. Tighten with wrench another

1/2-3/4 turn.

Lubricate all the o-rings on the support tubes

with the appropriate lubricant. Install each until

the thread has bottomed out in the knuckle using

wrench (A11284-00). Torque 10-15 lbs•in (1.13-

1.7 Nm).

Ransburg

LN-9263-08.5

CASCADE SIDE

OF KNUCKLE

FIBER OPTIC CABLE

F.O. O-RING

F.O. FITTING

F.O. TRANSMITTER

F.O. TRANSMITTER

RETAINING NUT

78279-00

F.O. TOOL

KNUCKLE