beautypg.com

Ransburg, Rma-303 dual purge/direct charge - maintenance, Cascade removal/replacement – Ransburg RMA Dual Purge Direct A12300 User Manual

Page 76: Fluid tube removal/replacement

background image

RMA-303 Dual Purge/Direct Charge - Maintenance

71

Figure 42: Fluid Tube Removal

Fluid Tube Replacement

Lubricate all o-rings with A11545-00 o-ring lu-

br-icant. Push the fluid tube into the pocket of

the atomizer body. Seat the tube by pushing

while rocking the tube from side to side. Install

the fluid tube retaining nut over the tube. Tighten

the retaining nut firmly tight using the removal tool

in a clockwise direction. Tighten to 65-75 lbs•in

(7.34-8.47 Nm).

Rear Plate/Rear Manifold/Cascade

Removal and Replacement

Rear Plate, Rear Manifold, Cascade

Removal

Remove the cup wash and the fluid coil fitting from

the rear valve manifold. Both are removed by

turning counter-clockwise. The ferrule(s) should

Figure 43: Rear Valve Manifold Removal

Cascade Removal/Replacement

Cascade Removal

Remove all components, shroud, break-away ring,

rear plate, and rear manifold. (See "Rear Plate/

Rear Manifold/Cascade Removal/Replacement"

in the "Maintenance" section.) Pull the cascade

straight out of the knuckle.

Cascade Replacement

Use a small amount of dielectric grease

(LSCH0009) on the end of the spring of the cas-

cade and the wire in the knuckle. Also, apply a

small amount of grease into the concentric rings

around the spring.

be retained with the coil and the cup wash line.

Remove the five (5) air bolts using a wide bladed

screwdriver.

Pull both the rear valve manifold and the rear

plate away from the applicator. Loosen the fiber

optic and low voltage cascade connector set

screws about four turns with a 3/32" hex wrench.

Push the cascade connector out of the rear plate

towards the front of the applicator, pull the fiber

optic cable out. Both the rear plate and the rear

valve manifold may now be removed.

Fluid Tube Removal/Replacement

Fluid Tube Removal (Turbine Removed)

Using the fluid tip/tube removal tool (A11229-00),

place the pinned end of the tool towards the fluid

tube retaining nut and engage the pins into the

holes. Turn the tool counter-clockwise to remove

(see Figure 42).

Ransburg

LN-9263-08.5

COUNTER-CLOCKWISE

TO REMOVE FLUID

TUBE RETAINING NUT