Ransburg, Rma-303 dual purge/direct charge - maintenance – Ransburg RMA Dual Purge Direct A12300 User Manual
Page 69
RMA-303 Dual Purge/Direct Charge - Maintenance
64
Figure 23: Applicator Removal From Robot
Prior to removing applicator fom
the robot, the following tasks must be
completed:
• Robot put into E-stop mode, locked,
and tagged-out.
• All fluid passages are cleaned, purged
out, and depressurized.
Carefully remove the quick discon-
nect ring to insure any residual line
pressure has been relieved to atmo-
sphere.
W A R N I N G
!
Failure to replace a damaged bell
cup will cause premature turbine failure.
Warranty will not be honored if the bell
cup is damaged.
C A U T I O N
!
W A R N I N G
!
Bell Cup Removal/Replacement
NOTE
The bell cup should always be the first
component removed if any maintenance is
performed. Following the procedure will
minimize the risk of damage to the cup.
Lay the applicator on its side of a clean and
secure area, preferably an area where regular
mainten-ance is performed. Using the large open
end of the bell cup/combo wrench (A12061-00)
on the flats of the turbine shaft, carefully hold the
outside of the bell cup with one hand while ap-
plying a clockwise force to the wrench. The bell
cup is a right hand thread and must be turned
Figure 24: Bell Cup Removal
counter-clockwise to remove.
Place the bell cup in a safe, secure place. Carefully
inspect the cup for any damage. If there is any
damage to the cup, it must be replaced.
Ransburg
LN-9263-08.5
CCW
TO
REMOVE
HOLD
BELL CUP
WITH ONE
HAND
CW WITH
WRENCH