RMA-303 Dual Purge/Direct Charge - Operation

49

Ransburg

LN-9263-08.5

LOW VOLTAGE CABLE

INSTALLATION AND

REMOVAL

(See Figures 18, 19, 20, and 21)

A low voltage cable is provided to send power to

the high voltage cascade in the atomizer as well

as sending important information during operation

back to the MicroPak controls. One piece of the

cable is a permanent length of approximately

60-inches (1.5 meters) from the robot plate end.

The connecting cable can be ordered in various

lengths depending on the distance required to

reach from the robot arm to the MicroPak controller.

The ends of the cables have a male and female

quick disconnect end. This provides for a quick

and easy removal of the cable at the robot plate

if servicing or replacement is required.

It is important that the quick disconnect fitting be

secured to a good ground source. The A12241-XX

cable is supplied with a ground cable which can be

secured to the bulkhead connector and the other

end to a known ground source. The cable can also

be grounded by attaching the bulkhead connector

to a grounded bulkhead plate. The bulkhead plate

can be no more than 1/8-inch (3.18mm) in thick-

ness. The bracket should be made as in Figure

19 to hold the connector from turning. To mate

the connectors, align the raised key section of the

cable on the applicator end with the key groove

of the cable that goes to the MicroPak. Push the

male end into the mating connector until an audi-

ble click is heard. Tug on cable to ensure that it

is locked in place. To remove or disconnect the

cable, pull back on the male connector shell and

pull cable back at the same time. To remove this

section from the robot plate, remove the applicator.

Locate the set screw holding the flanged plastic

9 pin connector. Loosen with a 3/32" hex key

wrench. Pull the cable out from the robot plate

end. Install new cable in reverse direction, align

the 9 pin connector with the alignment mark on

the robot plate face and tighten set screw. Torque

5-10 lbs•in (0.56-1.13 Nm).

W A R N I N G

!

†

Cable connector shell must be elec-

trically grounded. Electrical noise or other

interference may result!