B.1.4 COMMUNICATION TRANSACTION EXAMPLES

Transaction A Example - Host or SUPERVISOR-PC requests 9 bytes of data beginning at hexa-
decimal memory address 1000H from the instrument at Datalink address 03.

1.

Host or SUPERVISOR-PC sends INTERROGATE message.

01111110 11100011 00001001 00000000 00010000 11111100

SOH Command NUM LO ADD HI ADD LRC
+ I.A.

2.

Instrument sends RESPONSE message.

01111110 00100011 00001001 00000000 00010000 XXXXX XXXXX XXXXX LRC

SOH Command NUM LO ADD HI ADD Data 1..................Data 9
+ I.A.

Transaction B Example - Host or SUPERVISOR-PC sends two bytes of new data, to be loaded
into the instrument at Datalink address 03 beginning at hexadecimal memory address 1000H.

1.

Host sends CHANGE message.

01111110 10100011 00000010 00000000 00010000 00001000 00001100 11001001

SOH Command NUM LO ADD HI ADD Data 1 Data 2 LRC
+ I.A.

2.

Instrument sends RESPONSE message.

01111110 00100011 00000010 00000000 00010000 00001000 00001100 01001001

SOH Command NUM LO ADD HI ADD Data 1 Data 2 LRC
+ I.A.

3.

Host sends ACKNOWLEDGE message.

01111110 10000011

SOH Command
+ I.A.

4.

Instrument performs the change requested at end of the current program scan.

Appendix B. Communications

B-5