3.3 FRONT PANEL PUSH BUTTONS

The front panel push buttons are repeated here from Section 1 because they are used in the engi-
neering mode display overlay examples to enter a key password, display a datapoint, and alter a
datapoint.

To the right of the display is the vertical keypad and directly beneath the display is the horizontal
keypad
. Both keypads have functioning push buttons that are dependent on the instrument mode
of operation which can be either operator mode or engineering mode. Mode selection is made
with the Mode (

) push button on the horizontal keypad. Engineering mode is entered to make the

necessary selections for the operator displays and to configure the Datalink port; otherwise, the in-
strument is left in operator mode for process applications. The vertical keypad is dedicated only to
engineering mode functions and has no effect in operator mode. Both keypads are described as
follows:

Horizontal Keypad:

Push Button

Title

Operator Mode

Engineering Mode

1

Page back to previous display.

Back to previous entry line function.

2

Page forward to next display.

Pages the configure/display functions.

3

Moves Quad Bargraph pointer.

Executes an enter or display function.

Mode

Operator/Engineering mode select; Alarm reset.

Vertical Keypad:

Title

Engineering Mode

Ascending
Character
Select

Displays one character at a time in ascending alphanumeric order;
is released when the desired character, number, or symbol appears
on the engineering mode data entry line.

Descending
Character
Select

Displays one character at a time in descending alphanumeric
order; is released when the desired character, number, or symbol
appears on the engineering mode data entry line.

Shift Left

Shifts selected character one position left on the engineering mode
data entry line each time this push button is pressed.

Shift Right

Shifts characters on engineering mode data entry line one
character position right each time this push button is pressed.

2

3

1

53IT5100 Indicator/Totalizer