beautypg.com

3 heater kit, 115 vac – Controlled Products Systems Group 1603-080 User Manual

Page 33

background image

1603-065-T-4-13

31

Shut off AC power to operator.
Turn off DC power switch on certain models.

8.3 Heater Kit

To avoid the gearbox oil from freezing an optional heater kit (115 VAC - P/N 1601-092) is recommended in areas where
temperatures routinely drop below 40°F (4°C).

Mount heater with 2 lock nuts.
Place the 2 supplied
washers between the
operator wall and
the heater to
create an
air gap.

1

2

Connect the heater wires.

4

AUTO

- Normal setting. Automatically turns the

heater ON when the temperature drops below 40°F
inside the housing, and turns the heater OFF when
the temperature rises above 40°F inside the housing.

OFF

- Turns the heater off.

ON

- Turns the heater on continuously. The heater

will become VERY HOT when running continuously.

Heater switch settings.

5

Neutral

Hot

115 VAC

DANGER

HIGH VOLTAGE!

Threaded

Housing Stud

(Existing)

Threaded

Housing Stud

(Existing)

Washer

Lock Nut

Lock Nut

Washer

1

2

Route heater wires as shown. Use supplied
wire stays and existing wire restrainers.
Keep wires clear of all moving parts.

3

CAUTION: Heat will be
transferred to the outside
wall of the operator if NO
air gap exists between the
heater and the inside wall
of the operator.

2

5

Wire Stays

Existing Wire Restrainers

Air Gap

3

3

3

DANGER

HOT!

4

1

This manual is related to the following products: