10

Function is dependent on the setting of programming SW 1, switch 6.
When switch 6 is OFF, this input will cause the
operator to rotate the arm to the up position. If the arm
is in the down cycle, this input will reverse the arm to
the up position. If this terminal has a constant input,
the arm will remain in the up position regardless of any
down input or timer command to rotate down.
When switch 6 is ON, this input will cause the operator
to rotate the arm to the up position when it is down,
and will cause the operator to rotate the arm to the
down position when it is up. If the auto timer is turned
ON (Not recommended if switch 6 is ON), this input
will override the timer and rotate the arm to the down
position. If the arm is in the down cycle, this input will
reverse the arm to the up position.

DANGER

HIGH VOLTAGE!

NC NO

1 2 3 4 5 6 7 8 9 10 11 12 13 14

2.3 Main Terminal Description

Function is dependent on the setting of programming SW 1, switches 1 and 4.
With switch 1 OFF and switch 4 ON, activation and then deactivation of
this input will rotate the arm to the down position, provided that the
deactivation of the input happens while the arm is in the full up
position. This input will override the auto timer if it is turned ON. If the
arm is in the down position, traveling in the down cycle, or traveling in
the up cycle, activation and deactivation of this input has no effect on
the arm.
With switches 1 and 4 are ON, activation and then deactivation of this
input will rotate the arm to the down position after it reaches the full
up position regardless of when the deactivation of the input occurred.
When switch 4 is OFF, this input is identical to the reverse input,
terminal 9.

Function is dependent on the setting
of programming SW 1, switch 8.
When switch 8 is ON, the
function of this input is
identical to terminal 6.
When switch 8 is OFF,
this terminal becomes
the logic output of the up
loop detector.

Function is dependent on the setting
of programming SW 1, switch 5.
When switch 5 is OFF,
activation of the down
loop will activate the
relay.
When switch 5 is ON,
activation of the UP loop
will activate the relay.

When the arm is in the down position,
activation of this input has no effect.
When the arm is in the up position,
activation of this input will prevent the arm
from rotating to the down position. If the
arm is in the down cycle, activation of this
input will reverse the arm to the up
position.

This input is used when sequencing the
1601 with a slide or swing gate operator in
PAMS applications. Activation of this input
will rotate the arm to the up position one
time, and activates the enable up input.

This input is used when sequencing the
1601 with a slide or swing gate operator in
PAMS applications. This input is only active
after a MOMENTARY UP input is received.
Activation of this input will rotate the arm
to the up position or reverse an arm in the
down cycle to the up position.

Relay contacts can be set
for Normally Open (NO)
or Normally
Closed (NC)
operation.

Contact rating
is 1 amp
maximum at 24 Volts.

NC

NO

11

12
13

10

9

6

8

7

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

SW 1

1

ON

2

3

4

5

6

7

8

Low V

oltage Common

Dr
y Relay Contact

Dr
y Relay Contact

ENABLE UP Input

MOMENT

AR
Y UP Input

REVERSE Input

DOWN/REVERSE Input

UP INPUT or UP LOOP Output

UP Input

24 V

AC - 250 mamp. max.

115 V

AC Motor

115 V

AC Motor

115 V

AC Power

115 V

AC Neutral