5 operator timer on entry lane (no down loop), Ab b, Dual channel – Controlled Products Systems Group 1603-080 User Manual
Page 21: Arming loop, 1 ft. minimum distance

1603-065-T-4-13
19
SW 1
1
ON
2
3
4
5
6
7
8
9409
Dual Channel
4.5 Operator Timer ON Entry Lane (No Down Loop)
REVERSE
SENSITIVITY
TIME
DELAY
POWER
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
NC NO
UP
LOOP
DOWN
LOOP
1 2 3 4 5
6
7 8 9 10 11 12 13
14
1601
SW 1, switch 4 is OFF.
SW 1, switch 7 is ON (Timer). The arm will
rotate down after the timer has timed out.
Speed Bump
Reverse Loop
Reverse Loop
Access
Control
Device
If the arming loop is not used, then a Single Channel Loop Detector can be
used (9410) in the down loop port. Connect the reverse loops to loop 1 on this
detector. Connect the access control device directly to main terminal 6 and 14.
Com
NO
Com
NO
SW 1
SW 2
Adjust from 1 second
(full counter clockwise)
to approximately 59
seconds (full clockwise).
1 59
TIME
DELAY
A
A
B
B
Arming Loop Note: The arming loop only allows the access control device to
function when a vehicle is on the loop, otherwise it will not function. This prevents
pedestrians from gaining access through the vehicular gate.
Reverse Loop Note: The reverse loops will prevent the arm from closing on a
vehicle remaining in the arm’s pathway. The timer will restart the countdown any
time the reverse loop gets activated.
Reverse loops wired in series.
Arming Loop
for Access
Control Device
(Optional)
Helps increase distance
and time between vehicles.
Main Terminal
Note: Make sure that a vehicle
can NOT fit in the area
between the reverse loops.
1 Ft. Minimum Distance