4 dual operator installation (primary/secondary), Inside proper ty, Primary operator circuit board – Controlled Products Systems Group 1603-080 User Manual
Page 10: 1601 secondary operator circuit board, Left side right side, When using reverse loops

1603-065-T-4-13
8
Install dual operators the same as installing two single operators except for:
•
There are no end cap sections used.
•
Secondary spikes will face and rotate the opposite direction as the primary spikes
(Retract away from oncoming traffic).
•
Operators need to be wired together with an interconnection cable (Sold separately).
•
Each operator requires AC power.
•
Both operator’s DIP-switches (SW 1, SW 2) must be set the same.
•
Connect all loop detectors and access control devices to the PRIMARY operator ONLY.
REVERSE
SENSITIVITY
TIME
DELAY
POWER
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
NC NO
UP
LOOP
DOWN
LOOP
1 2 3 4 5
6 7
8
9
10 11
12 13 14
1601
Sold separately from DoorKing.
4 wires used (8 - 18 AWG wires total).
Primary Operator
Circuit Board
REVERSE
SENSITIVITY
TIME
DELAY
POWER
1
ON
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
NC NO
UP
LOOP
DOWN
LOOP
1 2 3 4 5
6
7
8 9
10 11 12 13
14
1601
Secondary Operator
Circuit Board
SW 1
SW 1, switch 4 is ON.
SW 1, switch 5 is OFF.
SW 1, switch 8 is OFF.
When using Reverse Loops:
DIP-Switch settings: SW 1, switch 4 is OFF. SW 1, switch 5 is OFF. SW 1, switch 8 is OFF. Set other DIP-switches
based on gate operation preferences. See page 19 for reverse loop wiring.
Interconnection cable: The BROWN wire must be connected to SECONDARY TERMINAL #9 along with the
GRAY wire. All other terminal wire connections are the same as shown above.
Set other DIP-switches
based on gate operation
preferences.
Yellow
Brown
Gray
Orange
Yellow
Brown
Reverse loops
Gray
Orange
UP Loop Detector
Settings using
Down Loop
DOWN Loop Detector
Illustration shows four 3-ft spike sections (12 ft. of spikes).
Each operator controls two 3-ft spike sections.
Inside Proper
ty
Traffic Lane
1.4 Dual Operator Installation (Primary/Secondary)
For use in areas needing more than three 3-Ft spike sections (9 ft. of spikes) in a traffic lane.
Up to six 3-Ft spike sections (18 ft. of spikes) can be used with dual operators.
Jumper
Wire
Jumper
Wire
1
ON
2
3
4
5
6
7
8
Primary/Secondary
Interconnection Cable
Traffic Direction
Traffic Direction
Secondary
Operator
Primary
Operator
LEFT Side
RIGHT Side