beautypg.com

Option 2 - override multiple down commands, Sw2, switch 3 on – Controlled Products Systems Group 1603-080 User Manual

Page 26

background image

1603-065-T-4-13

24

Down Loop

Operator will count each valid UP command from each vehicle as they enter

.

Down Loop

Down Loop

Access Control Device

1

1

4

3

5

5

Note:
If an UP command is given
while the arm is lowering, the
arm will raise.

Option 2 - Override Multiple DOWN Commands

SW2, Switch 3 ON

Valid UP command given

Operator
will raise
arm

1

2

3

4

5

Operator will
override
multiple
DOWN
commands.

Arm will
remain up

while counting
the vehicles
activating
the down loop.

Basic operator UP/DOWN cycle:

A.

Valid UP command from the

access control device will raise arm.

B.

Vehicle activating and clearing

the down loop will lower the arm.

Operator will
lower the arm
ONLY after the
last vehicle
activates
then clears
the down loop.

This option allows the access
control device and the barrier gate
operator to have multiple vehicles
in the area between them. The
operator will count all the valid
UP commands received and
require a down loop activation for
each one. The arm will lower only
after the last vehicle activates
then clears the down loop.

Remote transmitters are NOT
recommended for this option
because one vehicle’s remote
can accidently be pressed
multiple times which will get
counted by the operator as
multiple vehicles.

2