beautypg.com

Fluid Components International GF90_GF92 User Manual

Page 51

background image

Doc. No. 06EN003229 Rev. H

47

GF Series Flow Meter Models GF90/GF92

FLUID COMPONENTS INTERNATIONAL LLC

http://www.fluidcomponents.com

IF NOT EOF(1) THEN

' LOC(1) gives the number of characters waiting.
GFInput$ = GFInput$ + INPUT$ (LOC(1), #1)

' Gather at least one full display of information
IF INSTR(GFInput$, "CH1:") THEN

DO UNTIL INSTR(more GFInput$, "CH:")

moreGFInput$ = moreGFInput$ + INPUT$(LOC(1), #1)

LOOP

GFInput$ = GFInput$ + moreGFInput$

' Parse and print the flow rate and temperature
n% = INSTR(GFInput$, "CH:")
FlowRate! = VAL(MID$(GFInput$, n% +5))
n% = INSTR(GFInput$, "CH2:")
Temperature! = Val(MID$(GFInput$, n% + 5))

PRINT FlowRate!, Temperature!

END IF

END IF

LOOP

CLOSE

' End communications.

END

error.trap:
RESUME NEXT

Figure 31A - Series Serial Communication Code Example Cont’d.