Object 1001h: error register, Object 1003h: pre-defined error field – BEI Sensors THK4 User Manual
Page 20

www.beisensors.com
page
20/57
Object 1001h: Error Register
This object is used by the device to display internal faults. When a fault is detected, the corresponding bit
is therefore activated.
The following errors are supported:
Bit
Description
Comments
0
Generic Error
The generic error is signaled at any error situation.
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0 -
Unsigned
8
N/A
ro
no
Object 1003h: Pre-Defined Error Field
The object holds the errors that have occurred on the device and have been signaled via the Emergency
Object.
The error code is located in the least significant word
Additional Information is located in the most significant word
Subindex 0 contains the number of recorded errors
Subindex Description
Data Type
Default Value
Access
Restore after
BootUp
0
Number of recorded errors
Unsigned 8
0
rw
no
1
Most recent errors
Unsigned 32
-
ro
no
2
Second to last error
Unsigned 32
-
ro
no
…
10
Clearing Error Log
The error log can be cleared by writing 0 to subindex 0 of object 1003.