Programmable parameters – BEI Sensors THK4 User Manual
Page 15
www.beisensors.com
page
15/57
5. Programmable Parameters
Objects are based on the CiA 406 DS V3.2: CANopen profile for encoders (
)
Command
Function
Telegram
Description
22h
Domain Download
Request
Parameter to Encoderr
23h, 27h, 2Bh, 2Fh (*) Domain Download
Request
Parameter to Encoder (Bytes
indicated)
60h
Domain Download
Confirmation
Parameter received
40h
Domain Upload
Request
Parameter request
43h, 47h, 4Bh, 4Fh (*) Domain Upload
Reply
Parameter to Master (Bytes
indicated)
80 h
Warning
Reply
Transmission error
Tab. 10 General Command Byte Description
(*)The value of the command byte depends on the data length of the called parameter:
Command
Data length
Data type
Command
Data length
Data type
43h
4 Byte
Unsigned 32
23h
4 Byte
Unsigned 32
47h
3 Byte
Unsigned 24
27h
3 Byte
Unsigned 24
4Bh
2 Byte
Unsigned 16
2Bh
2 Byte
Unsigned 16
4Fh
1 Byte
Unsigned 8
2Fh
1 Byte
Unsigned 8
Tab. 11 Detailed Command Byte Description
Object Dictionary
The data transmission according to CAL is realized
exclusively by object oriented data messages. The
objects are classified in groups by an index record.
Each index entry can be subdivided by sub-indices.
The overall layout of the standard object dictionary is
shown beside:
Index (hex) Object
0000
not used
0001-001F Static Data Types
0020-003F Complex Data Types
0040-005F Manufacturer Specific Data Types
0060-0FFF Reserved for further use
1000-1FFF Communication Profile Area
2000-5FFF Manufacturer Specific Profile Area
6000-9FFF Standardized Device Profile Area
A000-FFFF Reserved for further use
Tab. 12 Overview Object Dictionary