3 storing parameter, 1 list of storable parameter, 1 storing procedure – BEI Sensors THK4 User Manual
Page 13
![background image](/manuals/327338/13/background.png)
www.beisensors.com
page
13/57
4.3 Storing Parameter
4.3.1 List of storable Parameter
Object Index Object Description
1005h
COB-ID Sync
100Ch
Guard Time
100Dh
Life Time Factor
1016h
Consumer Heartbeat Time
1017h
Producer Heartbeat Time
1020h
Verify configuration
1800h
Communication parameter PDO 1
1801h
Communication parameter PDO 2
1A00h
Transmit PDO1 Mapping Parameter
1A01h
Transmit PDO2 Mapping Parameter
2100h
Operating Parameters
2101h
Resolution per Revolution
2102h
Total Resolution
2103h
Preset Value
2104h
Limit Switch, min.
2105h
Limit Switch, max.
2160h
Customer Storage
2200h
Cyclic Timer
3000h
Node Number
3001h
Baud rate
6000h
Operating Parameter
6001h
Steps per Revolution
6002h
Total Resolution
6003h
Preset Value
6200h
Cyclic Timer
Tab. 9 List of Storable Parameters
4.3.1 Storing Procedure
The parameter settings can be stored in a non-
volatile E
2
PROM. The parameter settings are
stored in RAM when being programmed.
When all the parameters are set and proved,